Head - Design - Chiller (8-12 yrs)
Job Description for the position of Head Design- Chiller
Location : Indore
Our client is a company makes HVAC SYSTEM product.
Its manufactures of Screw & Scroll Chillers system, Heat pumps, Thermal storage tanks, solar heat pump, Condenser. All products are used for residential and commercial purposes.
RESPONSIBILITIES :
- Designing of Heat pump, Chillers, Solar systems & storage system
- The HVAC cycle is the same on Air Conditioners, VRV/VRF, Chillers, and Heat Pumps. The difference in these is its application and the size of its components.
- AC and VRV, refrigerant flow in between indoor and outdoor units to manage the room temperature.
- In Chillers and Heat, Pump refrigerant flows only in the outdoor unit, and heat exchanged water goes to indoor units to manage the room temperature.
- Screw, Scroll, and Solar and Heat Pumps:- Maintenance of water-cooled Screw chillers, Air-cooled Screw Chillers, mini scroll chillers, heat pumps, and air conditioners.
- Commissioning: - Commissioning of all types of Chillers & Heat Pumps manufactured by many brands company.
- De-Scaling on Heat pump on all brands and hot water storage tank to reduce leakage.
- Mechanical Design of HVAC products
- Compressor : Use screw & scroll compressor in the machine. Check and change oil, oil heater, current, sound, contractor, relay connectivity, Suction, and the discharge port of refrigerants.
- Evaporator & Condenser : Use shell & tube type Evaporator, and Fins and shell & tube type condenser, in which check leakage, the gap between fins, de-scaling of condenser, sensor calibration.
- Capacitor : Only used for single face compressor and condensing fans to give starting torque to start the motor, and support during running.
- Expansion Valve & Filter Drier : Major complaint about both components has chocking on it. Due to brazing dust of copper tubes missed with refrigerant and cause chocking on it.
- Thermostat : This is used to sense the temperature of the room and refrigerant on the coil.
- Automatic panel : Make automatic panel box for on & off of the pump, electric elements with contractor, and subzero.
- Reduce Compressor failure : To reduce the problem of Compressor failure and compressor ground by using a mega meter to check time to time its mega meter value and resistance value.
- Check Voltage and current during the operation by using multicenter and use single-phase protection relay to protect compressor terminal and internal binding.